University of Tasmania
Browse

An automated algorithm for the detection of cortical interruptions and its underlying loss of trabecular bone; A reproducibility study

Download (2.37 MB)
journal contribution
posted on 2023-05-20, 05:12 authored by Peters, M, de Jong, J, Scharmga, A, van Tubergen, A, Geusens, P, Loeffen, D, Weijers, R, Boyd, SK, Barnabe, C, Kathryn Stok, van Rietbergen, B, van den Bergh, J

Background: We developed a semi-automated algorithm that detects cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT), and extended it with trabecular void volume measurement. In this study we tested the reproducibility of the algorithm using scan/re-scan data.

Methods: Second and third metacarpophalangeal joints of 21 subjects (mean age 49 (SD 11) years, 17 early rheumatoid arthritis and 4 undifferentiated arthritis, all diagnosed < 1 year ago) were imaged twice by HR-pQCT on the same day with repositioning between scans. The images were analyzed twice by one operator (OP1) and once by an additional operator (OP2), who independently corrected the bone contours when necessary. The number, surface and volume of interruptions per joint were obtained. Intra- and inter-operator reliability and intra-operator reproducibility were determined by intra-class correlation coefficients (ICC). Intra-operator reproducibility errors were determined as the least significant change (LSCSD).

Results: Per joint, the mean number of interruptions was 3.1 (SD 3.6), mean interruption surface 4.2 (SD 7.2) mm2, and mean interruption volume 3.5 (SD 10.6) mm3 for OP1. Intra- and inter-operator reliability was excellent for the cortical interruption parameters (ICC ≥0.91), except good for the inter-operator reliability of the interruption surface (ICC = 0.70). The LSCSD per joint was 4.2 for the number of interruptions, 5.8 mm2 for interruption surface, and 3.2 mm3 for interruption volume.

Conclusions: The algorithm was highly reproducible in the detection of cortical interruptions and their volume. Based on the LSC findings, the potential value of this algorithm for monitoring structural damage in the joints in early arthritis patients needs to be tested in clinical studies.

History

Publication title

BMC Medical Imaging

Volume

18

Pagination

13

ISSN

1471-2342

Department/School

Menzies Institute for Medical Research

Publisher

BioMed Central Ltd.

Place of publication

United Kingdom

Rights statement

Copyright 2018 The Authors. Licensed under Creative Commons Attribution 4.0 International (CC BY 4.0) https://creativecommons.org/licenses/by/4.0/

Repository Status

  • Open

Socio-economic Objectives

Expanding knowledge in engineering

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC