posted on 2023-05-18, 00:01 authored by Senior, R, Monaghan, M, Main, ML, Zamorano, JL, Tiemann, K, Agati, L, Weissman, NJ, Klein, AL, Thomas MarwickThomas Marwick, Ahmad, M, DeMaria, AN, Zabalgoitia, M, Becher, H, Kaul, S, Udelson, JE, Wackers, FJ, Walovitch, RC, Picard, MH
Aims To determine if perfusion stress echocardiography (PSE) with ImagifyTM (perflubutane polymer microspheres) is comparable to stress perfusion imaging using 99mTc single photon emission computed tomography (SPECT) for coronary artery disease (CAD) detection. PSE is a novel technique for evaluating myocardial perfusion. RAMP (real-time assessment of myocardial perfusion)-1 and -2 were international, Phase 3 trials that evaluated the ability of PSE with Imagify, to detect CAD.
Methods and results Chronic, stable, chest pain patients (n = 662) underwent Imagify PSE and gated SPECT imaging at rest and during dipyridamole stress. Independent blinded cardiologists [three PSE readers per trial, and four SPECT readers (one for RAMP-1, three for RAMP-2)] interpreted images. CAD was defined by quantitative coronary angiography or 90-day outcome with clinical review. Accuracy, sensitivity, and specificity were evaluated using non-inferiority analysis (one-sided alpha = 0.025) compared with SPECT. SPECT results for RAMP-1 and -2 were: accuracy (70%, 67%), sensitivity (78%, 61%), and specificity (64%, 76%). Accuracy of all six PSE readers was non-inferior to SPECT (66-71%, P <=0.004). Four demonstrated non-inferior sensitivity (68-77%, P<= 0.002), three demonstrated noninferior specificity (72-88%, P <= 0.013). Three PSE readers (RAMP-2) were superior for sensitivity. Two PSE readers (RAMP-1) were superior for specificity. Area under the multi-reader receiver operating characteristics curve (0.72) was equal for both modalities. Majority of adverse events followed dipyridamole dosing, and were mild, transient, and required no treatment.
Conclusions Imagify PSE was well-tolerated. Its diagnostic performance in chest pain patients is comparable with SPECT perfusion imaging.

History

Publication title

European Journal of Echocardiography

Volume

10

Pagination

26-35

ISSN

1525-2167

Department/School

Menzies Institute for Medical Research

Publisher

Oxford University Press

Place of publication

United Kingdom

Rights statement

Copyright 2009 Oxford University Press

Repository Status

  • Restricted

Socio-economic Objectives

Clinical health not elsewhere classified

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC