Purpose: Artificial intelligence (AI) has been shown as a diagnostic tool for glaucoma detection through imaging modalities. However, these tools are yet to be deployed into clinical practice. This meta-analysis determined overall AI performance for glaucoma diagnosis and identified potential factors affecting their implementation.

Methods: We searched databases (Embase, Medline, Web of Science, and Scopus) for studies that developed or investigated the use of AI for glaucoma detection using fundus and optical coherence tomography (OCT) images. A bivariate random-effects model was used to determine the summary estimates for diagnostic outcomes. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis of Diagnostic Test Accuracy (PRISMA-DTA) extension was followed, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used for bias and applicability assessment.

Results:Seventy-nine articles met inclusion criteria, with a subset of 66 containing adequate data for quantitative analysis. The pooled area under receiver operating characteristic curve across all studies for glaucoma detection was 96.3%, with a sensitivity of 92.0% (95% confidence interval: 89.0-94.0) and specificity of 94.0% (95% confidence interval: 92.0-95.0). The pooled area under receiver operating characteristic curve on fundus and OCT images was 96.2% and 96.0%, respectively. Mixed data set and external data validation had unsatisfactory diagnostic outcomes.

Conclusion: Although AI has the potential to revolutionize glaucoma care, this meta-analysis highlights that before such algorithms can be implemented into clinical care, a number of issues need to be addressed. With substantial heterogeneity across studies, many factors were found to affect the diagnostic performance. We recommend implementing a standard diagnostic protocol for grading, implementing external data validation, and analysis across different ethnicity groups.

History

Publication title

Journal of Glaucoma

Volume

31

Issue

5

Pagination

285-299

ISSN

1536-481X

Department/School

Menzies Institute for Medical Research

Publisher

Wolters Kluwer Health

Place of publication

New York

Repository Status

  • Restricted

Socio-economic Objectives

Treatment of human diseases and conditions

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC