University of Tasmania
Browse
149681 - Quantitative CEST Imaging of Nuclear Overhauser Effects.pdf (3.61 MB)

Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke

Download (3.61 MB)
journal contribution
posted on 2023-05-21, 07:05 authored by Msayib, Y, Harston, GWJ, Ray, KJ, Larkin, JR, Brad SutherlandBrad Sutherland, Sheerin, F, Blockley, NP, Okell, TW, Jezzard, P, Baldwin, A, Sibson, NR, Kennedy, J, Chappell, MA

Purpose: In chemical exchange saturation transfer imaging, saturation effects between -2 to -5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model.

Methods: MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain.

Results: The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter (1.20±0.20) and in animals (1.27±0.20). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed.

Conclusion: Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.

History

Publication title

Magnetic Resonance in Medicine

Volume

88

Pagination

341-356

ISSN

0740-3194

Department/School

Tasmanian School of Medicine

Publisher

John Wiley & Sons Inc

Place of publication

111 River St, Hoboken, USA, Nj, 07030

Rights statement

© 2022 The Authors. This is an open access article under the terms of the Creative Commons Attribution International (CC BY 4.0) License, (https://creativecommons.org/licenses/by/4.0/) which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Repository Status

  • Open

Socio-economic Objectives

Treatment of human diseases and conditions; Expanding knowledge in the biomedical and clinical sciences

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC