Repetitive operations have been extensively used in the inverter compressor refrigeration industry. The approximately periodic disturbance caused by repetitive operations must be compensated to realize stable and high-efficiency operation. In this paper, a periodic disturbance observer (PDOB) is proposed to tackle the speed fluctuation of an inverter compressor in the low-frequency range. Periodic disturbance, consisting of a fundamental wave and corresponding harmonics, can thus be estimated and compensated; in addition, sensitivity and complementary sensitivity can reach a compromise through the use of a certain parameter. Aiming at a different operation environment, an adaptive notch filter based on the Steiglitz–McBride method is employed to estimate the fundamental frequency of periodic disturbance. Finally, the feasibility of our approach is verified by MATLAB simulation, and experiments are implemented to illustrate that speed fluctuation can be more effectively attenuated by the proposed method in comparison with general DOB.
History
Publication title
Energies
Volume
13
Issue
19
Article number
5014
Number
5014
Pagination
1-23
ISSN
1996-1073
Department/School
School of Engineering
Publisher
MDPIAG
Place of publication
Switzerland
Rights statement
Copyright 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).