posted on 2023-05-27, 12:53authored byWright, Alan Walter, 1932-
A description is given of the installation layout of the tunnel in its temporary building on the University site at Sandy Bay. Investigation of the tunnel flow has revealed that it is satisfactory from the points of view of symmetry and freedom from separation for the proposed blade testing. Curves for mass flow versus intake pressure drop have been drawn. An initial deflection in one piece of the drive Shaft causes considerable vibrations in the outlet section at approximately 400 r.p.m. away from that speed the vibrations are negligible. Suggestions are made within for future improvement in instrumentation to obtain the three dimensional flow measurement in the working section.
History
Publication status
Unpublished
Rights statement
Copyright 1956 the Author - The University is continuing to endeavour to trace the copyright owner(s) and in the meantime this item has been reproduced here in good faith. We would be pleased to hear from the copyright owner(s). Thesis (M.Eng.Sc.)--University of Tasmania, 1956